Standard for Fire Doors and Fire Windows 防火门窗标准目录

NFPA 80 Standard for Fire Doors and Fire Windows 1999 Edition

Chapter 1 General

Chapter 2 Swinging Doors with Builders Hardware

Chapter 3 Swinging Doors with Fire Door Hardware

Chapter 4 Horizontally Sliding Doors

Chapter 5 Vertically Sliding Fire Doors

Chapter 6 Rolling Steel Doors

Chapter 7 Special Purpose Horizontally Sliding Accordion or Folding Doors

Chapter 8 Hoistway Doors for Elevators and Dumbwaiters

Chapter 9 Chute Doors

Chapter 10 Fire Shutters

Chapter 11 Access Doors

Chapter 12 Service Counter Doors

Chapter 13 Fire Windows

Chapter 14 Glass Block

Chapter 15 Care and Maintenance

Chapter 16 Referenced Publications

Appendix A Explanatory Material

Appendix B Drawings of Fire Door Assemblies and Components

Appendix C Fire Doors: Protection of Conveyor Openings

Appendix D Illustration of Types of Fire Window Components

Appendix E Fire Door and Fire Window Classifications

Appendix F Surface Attachments to Swinging Door Faces

Appendix G Door Hardware Locations

Appendix H Types of Door Construction

Appendix I Special Purpose Doors

Appendix J Radiant Heat Transfer

Appendix K Referenced Publications

Formal Interpretation

Index

 

Document Scope: 1-1.1* This standard regulates the installation and maintenance of assemblies and devices used to protect openings in walls, floors, and ceilings against the spread of fire and smoke within, into, or out of buildings. The fire performance evaluation of these assemblies is tested in accordance with NFPA 251, Standard Methods of Tests of Fire Endurance of Building Construction and Materials, for horizontal access doors; NFPA 252, Standard Methods of Fire Tests of Door Assemblies, for fire doors and shutters; and NFPA 257, Standard on Fire Test for Window and Glass Block Assemblies, for fire windows and glass block. It is not the intent of this standard to establish the degree of protection required or to constitute the approval of any product. These are determined by the authority having jurisdiction. This standard is based on product and engineering practices recognized as acceptable at the date of issue. Therefore, the provisions of this standard are not intended to be applied retroactively to installations that were in compliance at the time of installation. 1-1.2 Incinerator doors, record room doors, and vault doors are not covered in this standard. For requirements on their installation, see NFPA 82, Standard on Incinerators and Waste and Linen Handling Systems and Equipment, and NFPA 232, Standard for the Protection of Records. 1-1.3 For requirements on the installation of hoistway doors for elevators and dumbwaiters, see the applicable sections of ASME/ANSI A17.1, Safety Code for Elevators and Escalators, or CAN 3-B44, Safety Code for Elevators. Requirements for horizontally sliding, vertically sliding, and swinging doors as used in this standard do not apply to hoistway doors for elevators and dumbwaiters. 1-1.4 This standard does not cover fire-resistant glazing materials and horizontally sliding accordion or folding assemblies fabricated for use as walls and tested as wall assemblies in accordance with NFPA 251, Standard Methods of Tests of Fire Endurance of Building Construction and Materials. Consult the authority having jurisdiction for the design and installation of such materials and assemblies.

Current Edition: 1999     Next Revision Cycle: Annual 2006